    Here to give you a brief introduction to the use of household gas stove five matters needing attention, we can look at!
Water pressure
The boiler before use, should first check the hydraulic pressure standards specified in the specification for the 1-1.2 bar, but in actual use, because there are some air heating system and the boiler, when the boiler is running, the exhaust valve of the air in the system continuously from the boiler with exhaust boiler, the pressure will fall without rules in the winter, when heating, the heating system of the thermal expansion of water system, water pressure will rise when the water pressure after cooling down again, this is a normal phenomenon, experimental results show that the wall of furnace pressure maintained at 0.5-1.5 as long as Pakistan completely does not affect the normal use of boiler, such as hydraulic pressure below 0.5 bar, may will cause the hot water or sometimes hot and sometimes cold can not start properly, such as the water pressure above 1.5 bar, when heating system pressure is too high, more than 3 bar, the boiler safety valve will discharge. Note that after the replenishment must turn off the boiler water switch knob, otherwise the boiler safety valve will drain more than, such as long-term travel or not admitted to the user, the water meter should be the total valve closed.
Two, electricity
The power socket of the boiler must be dedicated and well grounded, the boiler can be energized for a long time, especially in winter when no matter whether you stay, if the boiler has been filled with water, please be sure to electrify and set the antifreeze to prevent freezing of boiler. Setting method: twist the left most function rotary shaft button to non - zero, and the right side heating temperature knob turns to zero.
Three, bright red light
Boiler startup, such as flame is not detected will automatically light up red light, you should check the gas; battery 1, gas meter without electricity, 2 natural gas, the gas valve opening balance of less than 3, 4 gas meter fault, these phenomena can be verified by cooking gas stove, to find the reason and recovery. Manual reset start boiler. Reset method: the wall to the left side of the knob to RESET to the red light off.
Four, red and yellow alternate (immergas STAR)
Such as the emergence of wall mounted boiler, the boiler pressure is not enough, the need to manually add water pressure. Fill pressure: open the cold water valve, will be located in the boiler at the bottom of the "water filling switch" in a clockwise direction on observation of pressure gauge pointer to 1-1.2bar, and then quickly filled with water in a counterclockwise direction to close the switch.
Five, wall bottom leakage
If the internal pressure is higher than 3bar, the boiler will automatically drain. Encounter such a situation without panic, you only need to close in to confirm the "water filling switch", open the heating pipe on the running wind ", observe the boiler water pressure gauge pointer to 1-1.2bar, and then run the wind" can be closed.
Above to introduce the use of household gas heating stove five matters needing attention, we want to help!
 